Skip to main navigation Skip to search Skip to main content

Impact of Printing Orientations on the Trueness and Precision of Additively Fabricated Complete Denture Base Before and After Thermal Aging

  • Sara Tarq AL-Zayyat
  • , Turki Alshehri*
  • , Shahad T. Alameer
  • , Sarah Hajaj Althunayyan
  • , Reem A. Aldhafiri
  • , Zainab Albasry
  • , Abdulrahman A. Balhaddad
  • , Haidar Alalawi
  • , Mohammed M. Gad
  • *Corresponding author for this work
  • Ministry of Health, Saudi Arabia
  • Imam Abdulrahman Bin Faisal University
  • Ministry of National Guard Health Affairs

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: This in vitro study assessed the accuracy (trueness and precision) of different 3D-printed resin denture bases with 0°, 45°, and 90° printing orientations. Methods: Denture base was designed and fabricated using three 3D-printed denture base resins (DentaBASE, Denture 3D+, and FormLabs). Each resin was printed with its own printer and fabricated with different printing orientations, resulting in a total of 72 specimens (n = 8). Trueness and precision were evaluated before and after thermal aging using the superimposition method with best-fit alignment. The data were collected and analyzed using two-way ANOVA followed by post hoc Tukey’s test (α = 0.05). Results: The printing orientation significantly affected the trueness of 3D-printed resins (p < 0.001). The highest trueness was observed for NextDent at 0° printing orientation, while the lowest value was observed for ASIGA at 0° and 45° printing orientations. The precision of the denture base was significantly affected by different printing orientations for ASIGA (p = 0.006) and NextDent (p < 0.001) before thermal cycling, while the precision of FormLabs was significantly affected (p = 0.017) after thermal cycling. The highest precision was recorded for FormLabs at 45° printing orientation, while the lowest precision was observed for NextDent at 45° and 90° printing orientations. Moreover, the effect of thermal cycling on trueness was only significant for ASIGA at 0° printing orientation; however, the effect of thermal cycling on precision was significant for NextDent at 0° and 90° printing orientations. A 45° printing orientation provided the most accurate clinical fit. Conclusions: ASIGA showed the lowest trueness, while FormLabs exhibited the lowest precision, revealing performance differences between printers.

Original languageEnglish
Article number598
JournalDentistry Journal
Volume13
Issue number12
DOIs
StatePublished - Dec 2025

Keywords

  • 3D printing
  • accuracy
  • complete denture
  • printing orientation
  • printing parameters

Fingerprint

Dive into the research topics of 'Impact of Printing Orientations on the Trueness and Precision of Additively Fabricated Complete Denture Base Before and After Thermal Aging'. Together they form a unique fingerprint.

Cite this